rpi3: console: Use same "clock-less" setup scheme as RPi4

In the wake of the upcoming unification of the console setup code
between RPi3 and RPi4, extend the "clock-less" setup scheme to the
RPi3. This avoid programming any clocks or baud rate registers,
which makes the port more robust against GPU firmware changes.

Signed-off-by: Andre Przywara <andre.przywara@arm.com>
Change-Id: Ida83a963bb18a878997e9cbd55f8ceac6a2e1c1f
diff --git a/plat/rpi/rpi3/rpi3_bl2_setup.c b/plat/rpi/rpi3/rpi3_bl2_setup.c
index d64235a..db71817 100644
--- a/plat/rpi/rpi3/rpi3_bl2_setup.c
+++ b/plat/rpi/rpi3/rpi3_bl2_setup.c
@@ -51,7 +51,7 @@
 	meminfo_t *mem_layout = (meminfo_t *) arg1;
 
 	/* Initialize the console to provide early debug support */
-	rpi3_console_init(PLAT_RPI3_UART_CLK_IN_HZ);
+	rpi3_console_init();
 
 	/* Enable arch timer */
 	generic_delay_timer_init();