Use correct type when reading SCR register

The Secure Configuration Register is 64-bits in AArch64 and 32-bits in
AArch32. Use u_register_t instead of unsigned int to reflect this.

Change-Id: I51b69467baba36bf0cfaec2595dc8837b1566934
Signed-off-by: Louis Mayencourt <louis.mayencourt@arm.com>
diff --git a/plat/renesas/rcar/plat_pm.c b/plat/renesas/rcar/plat_pm.c
index e678da5..6fc47b9 100644
--- a/plat/renesas/rcar/plat_pm.c
+++ b/plat/renesas/rcar/plat_pm.c
@@ -1,5 +1,5 @@
 /*
- * Copyright (c) 2015-2019, Renesas Electronics Corporation. All rights reserved.
+ * Copyright (c) 2015-2020, Renesas Electronics Corporation. All rights reserved.
  *
  * SPDX-License-Identifier: BSD-3-Clause
  */
@@ -56,7 +56,7 @@
 
 static void rcar_cpu_standby(plat_local_state_t cpu_state)
 {
-	uint32_t scr_el3 = read_scr_el3();
+	u_register_t scr_el3 = read_scr_el3();
 
 	write_scr_el3(scr_el3 | SCR_IRQ_BIT);
 	dsb();